Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Rev. bras. oftalmol ; 77(4): 203-206, jul.-ago. 2018. tab, graf
Artigo em Português | LILACS | ID: biblio-959095

RESUMO

RESUMO O presente relato tem o objetivo de mostrar um caso incomum de Granulomatose com Poliangeíte (GPA), que previamente era denominada Granulomatose de Wegener. Trata-se de é uma doença multissistêmica, caracterizada por inflamação granulomatosa necrotizante e vasculite que envolve principalmente o trato respiratório superior e inferior, embora não raramente, exista comprometimento neurológico.


ABSTRACT This report aims to show an unusual case of granulomatosis with polyangeitis (GPA), previously known as Wegener's granulomatosis. It is a multisystemic disease characterized by necrotizing granulomatous inflammation and vasculitis involving mainly the upper and lower respiratory tract, although not infrequently, there is neurological impairment.


Assuntos
Humanos , Feminino , Adulto , Granulomatose com Poliangiite/complicações , Doenças dos Nervos Cranianos/etiologia , Esclera/transplante , Relatos de Casos , Metilprednisolona/uso terapêutico , Imageamento por Ressonância Magnética , Acuidade Visual , Esclerite/cirurgia , Granulomatose com Poliangiite/diagnóstico , Granulomatose com Poliangiite/terapia , Anticorpos Anticitoplasma de Neutrófilos , Doenças dos Nervos Cranianos/diagnóstico , Doenças dos Nervos Cranianos/terapia , Ciclofosfamida/uso terapêutico , Eletrodiagnóstico/métodos
2.
Arq. bras. oftalmol ; 81(1): 59-62, Jan.-Feb. 2018. graf
Artigo em Inglês | LILACS | ID: biblio-888186

RESUMO

ABSTRACT We report a case of central corneal perforation treated with an autologous lamellar scleral graft and histologic findings obtained after a subsequent penetrating keratoplasty. A corneal perforation within a large Pseudomonas ulcer in a 55-year-old male rigid gas permeable contact lens wearer was sealed by a lamellar scleral graft from the same eye, followed by an uneventful penetrating keratoplasty 6 months later. Histology of the excised button revealed that the well-apposed graft, which maintained the irregular arrangement of the scleral collagen fibers, was embedded in the corneal stroma over the deep blood vessels and a rupture in Descemet's membrane. The clinical and histologic findings showed that autologous lamellar scleral grafts can be successfully used for the emergency treatment of corneal perforation when a corneal transplant is not available. The distinctive scleral structure revealed by histology and the inadequate graft transparency indicate that visual rehabilitation of eyes with a central corneal perforation can be achieved only by a subsequent optic penetrating keratoplasty.


RESUMO Relatamos um caso de perfuração corneana central tratada com enxerto autólogo lamelar de esclera e os achados histológicos obtidos após ceratoplastia penetrante (CP) subsequente. Uma perfuração da córnea devido a uma grande úlcera por Pseudomonas em um usuário de lentes de contato rígidas gás permeável de 55 anos de idade foi selada por um enxerto escleral lamelar do mesmo olho, seguida de ceratoplastia penetrante, sem intercorrências, seis meses depois. A histologia do botão excisado revelou que um enxerto bem posicionado, que manteve o arranjo irregular das fibras de colágeno escleral, foi incorporado no estroma corneano sobre os vasos sanguíneos profundos e uma ruptura na membrana de Descemet. Os achados clínicos e histológicos demonstraram que o enxerto autônomo de esclerose lamelar pode ser usado com sucesso como tratamento de emergência da perfuração da córnea, quando o transplante de córnea não é possível. A estrutura escleral característica revelada pela histologia e a transparência inadequada do enxerto indicam que a reabilitação visual dos olhos com uma perfuração corneana central só pode ser alcançada através de uma ceratoplastia penetrante óptica subsequente.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Esclera/transplante , Ceratoplastia Penetrante/métodos , Perfuração da Córnea/cirurgia , Esclera/patologia , Transplante Autólogo , Acuidade Visual , Reprodutibilidade dos Testes , Resultado do Tratamento , Córnea/patologia , Perfuração da Córnea/patologia
3.
Rev. bras. oftalmol ; 75(2): 150-153, Mar.-Apr. 2016. graf
Artigo em Português | LILACS | ID: lil-779963

RESUMO

RESUMO Paciente do sexo feminino, portadora de glaucoma juvenil sem controle clínico adequado, foi submetida à trabeculectomia com mitomicina C, após a qual, desenvolveu hipotensão ocular refratária às medidas conservadoras, evoluindo com um quadro de maculopatia hipotônica. Foi realizado um implante de enxerto de retalho escleral de doador sobre a fístula, com resolução do quadro e ganho de acuidade visual. A enxertia de retalho escleral de doador mostrou-se uma terapia adequada para correção da hipotensão ocular por bolha hiperfiltrante pós trabeculectomia. O cirurgião deve considerar o emprego dessa técnica ao programar a revisão destes casos.


ABSTRACT A female patient with juvenile glaucoma without clinical control underwent a trabeculectomy with mitomycin C, and developed eye hypotension which did not respond to conservative treatment, with subsequent hypotonic maculopathy. The patient was treated using a scleral patch provided by a donor above the fistula, which improved intraocular pressure and visual acuity. The use of the scleral patch above the fistula seems an adequate therapy to treat ocular hypotension due to the over-filtering trabeculectomy bubble. The surgeon should consider this technique when planning surgical solutions for such cases.


Assuntos
Humanos , Feminino , Adulto , Doenças Retinianas/cirurgia , Doenças Retinianas/etiologia , Esclera/transplante , Trabeculectomia/efeitos adversos , Hipotensão Ocular/complicações , Hipotensão Ocular/induzido quimicamente , Macula Lutea/patologia , Doenças Retinianas/diagnóstico , Glaucoma/diagnóstico , Glaucoma/tratamento farmacológico , Mitomicina/efeitos adversos , Tomografia de Coerência Óptica , Microscopia com Lâmpada de Fenda , Macula Lutea/cirurgia
4.
Indian J Ophthalmol ; 2013 Jan-Feb; 61(1): 23-27
Artigo em Inglês | IMSEAR | ID: sea-145339

RESUMO

Aim: To report our experience with the fibrin sealant as a suture substitute for securing the human scleral patch graft during implantation of Ahmed glaucoma valve (AGV). Materials and Methods: A retrospective, non-comparative study of 12 eyes of 12 patients who underwent an AGV implantation with fibrin sealant for part of the procedure during June 2009 to September 2010. Results: The mean patient age was 21.5 ± 20.6 years. Male: Female ratio was 2 : 1. Seven (58.3%) patients were monocular. The indications for AGV were varied. The mean number of intra-ocular surgeries prior to an implantation of AGV was 1.8. The mean follow-up duration was 24.5 ± 17.9 weeks. There was a statistically significant reduction in the mean IOP and in the mean number of anti-glaucoma medications at the final visit compared to the pre-operative values (P < 0.01, paired t test). Conjunctival retraction was seen in 1 (8.3%) case. The scleral patch graft was retracted posteriorly in another (8.3%) case. There was no case of AGV tube exposure, tube-cornea touch, or conjunctival erosion. Vision threatening complication viz. late post-operative rhegmatogenous retinal detachment, unlikely to be related to the use of the fibrin sealant, occurred in 2 (16.6%) eyes. Conclusion: The fibrin sealant offers the advantages of safety and convenience to the placement of a scleral patch graft during an AGV implantation.


Assuntos
Adulto , Criança , Feminino , Adesivo Tecidual de Fibrina/uso terapêutico , Glaucoma/cirurgia , Humanos , Lactente , Masculino , Esclera/transplante , Transplante Homólogo/métodos
5.
Rev. bras. oftalmol ; 71(3): 155-159, maio-jun. 2012. ilus
Artigo em Português | LILACS | ID: lil-643912

RESUMO

OBJETIVO: Avaliação dos resultados da utilização de enxerto de espessura parcial de esclera autóloga para o tratamento das úlceras esclerais profundas, como complicação tardia da exérese de pterígio associada à betaterapia. MÉTODOS: Foram tratados doze olhos de doze pacientes, nove femininos e três masculinos, com idade variando entre 48 e 82 anos, média 65,2 anos. RESULTADOS: Houve boa integração do enxerto em todos os casos, com resultado funcional e cosmético favorável e sem complicações. CONCLUSÃO: Várias técnicas de enxertia tem sido propostas para o tratamento da úlcera escleral: esclera e dura-máter homólogas, derme, cartilagem auricular e periósteo autólogos. No entanto, o procedimento com esclera autóloga apresenta reais vantagens em relaçâo aos enxertos empregados anteriormente. Não há referências na literatura quanto ao emprego de enxerto de esclera autóloga de espessura parcial para o tratamento da úlcera escleral.


OBJETICVE: The authors describes a surgical technique that utilizes autologus delaminated scleral graft for the management of deep scleral ulcers. METHODS: In this technique that were perfomed in 12 eyes of 12 patients, 9 female, 3 male, age from 48 to 82 years, mean age 65.2 years. RESULTS: Occurred good integration of the grafting in all cases without any complications. CONCLUSION: Many techniques have been proposed for the management of scleral ulcers: sclera and dura-mater, autologus derme, auricular cartilage and autologus periosteum.There is no reference in relation to autologus scleral grafting with partial thickness for the treatment of scleral ulcers, as proposed in this study.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Lesões por Radiação/cirurgia , Lesões por Radiação/etiologia , Esclera/transplante , Partículas beta/efeitos adversos , Doenças da Esclera/cirurgia , Doenças da Esclera/etiologia , Complicações Pós-Operatórias , Esclera/efeitos da radiação , Retalhos Cirúrgicos , Partículas beta/uso terapêutico , Pterígio/cirurgia , Pterígio/radioterapia , Autoenxertos
6.
Indian J Ophthalmol ; 2011 May; 59(3): 235-238
Artigo em Inglês | IMSEAR | ID: sea-136179

RESUMO

Pre-existing scleral pathology is an important risk factor for globe rupture during scleral buckling procedures. We report here, the surgical management of an unexpected scleral pathology found at the scleral buckling procedure in a retinal detachment patient. A 77-year-old white female with retinal detachment underwent a scleral buckling procedure. The surgery was converted into a scleral graft procedure, as extreme scleral thinning was found intraoperatively. An alcohol-preserved donor sclera graft was used. The second surgery for definitive retinal alignment was performed two weeks later. The presented case of an unexpected scleral pathology in a retinal detachment patient was managed with a combination of scleral grafting and pars plana vitrectomy, without any major complications. The anatomical outcome was excellent and the scleral rupture was prevented; the visual outcome was satisfactory. A conversion of the scleral buckling procedure into a scleral graft procedure has proved to be safe and effective for unexpected scleral pathology.


Assuntos
Idoso , Feminino , Humanos , Reoperação , Descolamento Retiniano/cirurgia , Esclera/patologia , Esclera/transplante , Recurvamento da Esclera/efeitos adversos , Resultado do Tratamento , Vitrectomia
7.
Korean Journal of Ophthalmology ; : 317-322, 2011.
Artigo em Inglês | WPRIM | ID: wpr-138087

RESUMO

PURPOSE: To compare the surgical outcomes of the two different methods used for Ahmed Glaucoma Valve (AGV) implantation between the donor scleral graft method and the partial-thickness scleral flap method. METHODS: We retrospectively reviewed medical records of 28 eyes of 26 patients diagnosed as neovascular glaucoma followed by AGV implantation. Based on the surgical method, the included eyes were divided into two groups. In the graft group (n = 18), the drainage tube was inserted into the anterior chamber, and then covered with preserved donor sclera. In the flap group (n = 10), the drainage tube was inserted under the partial-thickness scleral flap, and then covered with the flap. We compared the postoperative intraocular pressure (IOP), surgical success rates, and postoperative complications between the two groups. RESULTS: Postoperative IOP was not significantly different between the two groups (p = 0.967, 0.495 at 12 months, 24 months, respectively, by the Mann-Whitney U-test). The mean success periods were 53.1 +/- 10.1 months in the graft group versus 50.9 +/- 9.4 months in the flap group (p = 0.882 by log rank test), and cumulative success rates were 77.8% and 80.0% at one year, respectively. However, tube migration occurred more frequently in the flap group than in the graft group (p = 0.037 by Fisher's exact test). CONCLUSIONS: In AGV surgery for neovascular glaucoma, the scleral graft method may be associated with relatively less complication about tube migration than the scleral flap method. The surgical results, however, were not statistically different.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Cirurgia Filtrante/métodos , Seguimentos , Implantes para Drenagem de Glaucoma , Glaucoma Neovascular/fisiopatologia , Pressão Intraocular , Estudos Retrospectivos , Esclera/transplante , Retalhos Cirúrgicos , Resultado do Tratamento
8.
Korean Journal of Ophthalmology ; : 317-322, 2011.
Artigo em Inglês | WPRIM | ID: wpr-138086

RESUMO

PURPOSE: To compare the surgical outcomes of the two different methods used for Ahmed Glaucoma Valve (AGV) implantation between the donor scleral graft method and the partial-thickness scleral flap method. METHODS: We retrospectively reviewed medical records of 28 eyes of 26 patients diagnosed as neovascular glaucoma followed by AGV implantation. Based on the surgical method, the included eyes were divided into two groups. In the graft group (n = 18), the drainage tube was inserted into the anterior chamber, and then covered with preserved donor sclera. In the flap group (n = 10), the drainage tube was inserted under the partial-thickness scleral flap, and then covered with the flap. We compared the postoperative intraocular pressure (IOP), surgical success rates, and postoperative complications between the two groups. RESULTS: Postoperative IOP was not significantly different between the two groups (p = 0.967, 0.495 at 12 months, 24 months, respectively, by the Mann-Whitney U-test). The mean success periods were 53.1 +/- 10.1 months in the graft group versus 50.9 +/- 9.4 months in the flap group (p = 0.882 by log rank test), and cumulative success rates were 77.8% and 80.0% at one year, respectively. However, tube migration occurred more frequently in the flap group than in the graft group (p = 0.037 by Fisher's exact test). CONCLUSIONS: In AGV surgery for neovascular glaucoma, the scleral graft method may be associated with relatively less complication about tube migration than the scleral flap method. The surgical results, however, were not statistically different.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Cirurgia Filtrante/métodos , Seguimentos , Implantes para Drenagem de Glaucoma , Glaucoma Neovascular/fisiopatologia , Pressão Intraocular , Estudos Retrospectivos , Esclera/transplante , Retalhos Cirúrgicos , Resultado do Tratamento
9.
Arq. bras. oftalmol ; 71(5): 623-628, set.-out. 2008. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-497210

RESUMO

PURPOSE: To evaluate the inflammatory response associated with the use of processed porcine pericardium and glycerin-preserved homologous sclera as silicone glaucoma drainage device coverage in a rabbit experimental model. METHODS: Eight New Zealand white rabbits' eyes received an equal-sized glycerin-preserved homologous scleral patch or a double-layered processed porcine pericardium that was sutured to the bare sclera covering a silicone tube. Conjunctival hyperemia was graded using the double-blind method during the immediate postoperative period and during the first, third, and seventh postoperative weeks. After the seventh week, the enucleated eyes were histopathologically examined. They were also evaluated for signs of patch graft melting, tube erosion and chemosis. RESULTS: There was no occurrence of graft melting or tube exposure, although porcine pericardium was associated with greater inflammation through clinical observation. Light microscopy revealed marked inflammation surrounding the porcine pericardium with foreign body granuloma formation. On the other hand, the sclera group presented milder inflammation with foreign body granulomas only around the sutures. CONCLUSIONS: Porcine pericardium is associated with significant inflammation when used as tube coverage in a rabbit model, at both histopathologic and clinical levels, when compared to glycerin-preserved homologous sclera during the seven-week follow-up period.


OBJETIVO: Avaliar a resposta inflamatória associada com o uso de pericárdio suíno processado e esclera homóloga preservada em glicerina no recobrimento de tubo de drenagem de silicone utilizado em cirurgia de glaucoma em modelo experimental. MÉTODOS: Oito olhos de 8 coelhos albinos da raça Nova Zelândia receberam enxertos do mesmo tamanho de esclera homóloga, preservada em glicerina ou pericárdio suíno processado, suturados à esclera recobrindo um tubo de silicone. Os olhos foram avaliados quanto à hiperemia conjuntival de modo mascarado na primeira, terceira e sétima semanas de pós-operatório. Após a sétima semana os olhos foram enucleados e submetidos a estudo histopatológico. Os olhos também foram avaliados quanto à presença de afinamento do enxerto, exposição do tubo e quemose. RESULTADOS: Não ocorreram casos de afinamento do enxerto ou exposição do tubo, porém o pericárdio suíno esteve associado clinicamente a uma maior inflamação. Achados à microscopia óptica incluíram intensa reação inflamatória em torno do enxerto de pericárdio com formação de granuloma do tipo corpo estranho. Por outro lado, no grupo que recebeu esclera, ocorreu formação de granulomas apenas em torno dos fios de sutura. CONCLUSÃO: O pericárdio suíno esteve associado a maior inflamação tanto à histopatologia quanto clinicamente, quando usado no recobrimento de tubo de silicone, em comparação à esclera homóloga preservada em glicerina, durante o período de acompanhamento de sete semanas.


Assuntos
Animais , Coelhos , Implantes para Drenagem de Glaucoma , Glaucoma/cirurgia , Pericárdio/transplante , Esclera/transplante , Reação a Corpo Estranho/patologia , Hiperemia/patologia , Pericárdio/patologia , Suínos , Esclera/patologia , Fatores de Tempo
10.
Arq. bras. oftalmol ; 70(6): 981-987, nov.-dez. 2007. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-474106

RESUMO

OBJETIVO: Avaliar a reação tecidual à implantação de enxertos homólogos de esclera e dura-máter. MÉTODOS: Foram realizadas cirurgias experimentais em 41 coelhos albinos da raça Nova Zelândia, sendo que dois coelhos foram selecionados, ao acaso, para serem doadores dos enxertos a serem utilizados no experimento. Trinta coelhos foram divididos em dois grupos: grupo D e grupo E, sendo submetidos à implantação dos tecidos homólogos e nove animais constituíram o grupo controle (grupo DE), submetidos à cirurgia sem enxertia. Os olhos foram enucleados e amostras foram colhidas em duas, seis e 12 semanas após o experimento, constituindo os subgrupos I, II e III. RESULTADOS: Foi realizada análise histopatológica qualitativa, além de estudo semiquantitativo comparativo da vascularização e infiltrado inflamatório na esclera e dura-máter transplantadas. Procedeu-se, também, a histomorfometria das medidas do lado dos enxertos com sistema analisador de imagens. Não houve diferença estatisticamente significante comparando-se a vascularização, infiltrado inflamatório e medidas do lado, entre os subgrupos I de esclera em relação à dura-máter, assim como nos subgrupos II. Não foram comparados os subgrupos III, pois foram observados somente fragmentos dos enxertos de dura-máter. CONCLUSÕES: O enxerto de dura-máter mostrou intensa reabsorção e progressiva substituição por tecido conjuntivo frouxo. O enxerto de esclera mostrou discreta reabsorção na periferia com formação de membrana fibrosa mais evidente, integrando este à esclera do hospedeiro.


PURPOSE: To evaluate tissue reaction to implantation of homologous scleral and dura mater grafts. METHODS: Experimental surgeries were performed on 41 albine New Zealand rabbits; two rabbits were selected at random to be graft donors. Thirty rabbits were divided into two groups: group D and group E, receiving grafts of homologous tissues. The remaining nine animals comprised the control group (DE) and were submitted to surgery but with no graft. The eyes were enucleated and samples collected two, six and 12 weeks after the experiment, comprising subgroups I, II and III. RESULTS: A qualitative histopathological analysis was performed together with a comparative semi-quantitative study on vascularization and inflammatory infiltrate in the transplanted sclera and dura mater. Histomorphometry was conducted based on measurements of the grafts with an image analyzing system. There was no statistically significant difference when comparing vascularization, inflammatory infiltrate and measurements between subgroup I in relation to sclera and dura mater, nor in subgroup II. Subgroup III was not compared, since only fragments of dura mater grafts were considered. CONCLUSIONS: The dura mater graft presented intense absorption and progressive replacement of loose connective tissue. And the scleral graft showed discreet absorption in the periphery with formation of a more evident fibrous membrane, integrating the graft into the host sclera.


Assuntos
Animais , Coelhos , Dura-Máter , Olho , Esclera , Corantes , Dura-Máter/patologia , Dura-Máter/transplante , Olho/patologia , Olho/transplante , Hematoxilina , Modelos Animais , Complicações Pós-Operatórias/patologia , Esclera/patologia , Esclera/transplante , Fatores de Tempo , Transplante Homólogo
11.
Ain-Shams Medical Journal. 2006; 57 (1-3): 275-284
em Inglês | IMEMR | ID: emr-75569

RESUMO

The aim of this study is to evaluate the short term result of the use of an autologous scleral implant during the non penetrating deep sclerectomy operation instead of the more expensive collagen implant. This study included 20 eyes of 20 patients with mean age of 42.3 +/- 8.1 years. All patients were indicated for conventional deep sclerectomy operation but we implanted an autologous scieral implant. This technique succeeded in declining the mean lop to 13.8 +/- 2.46 by the end of the follow up period. The final success rate was complete success in 65% of cases and qualified success in additional 30%. Nd: YAG goniopuncture was needed in about 40% of cases but the disadvantage was the early need for this procedure. The laser interference was needed around the third month postoperatively in most of the cases. The use of autologous scleral implant can give a comparable result to the use of the expensive collagen implant in controlling IOP but with less operative cost to the patient. The only problem in this technique is the more implant-induced fibrosis. So, Nd: YAG goniopuncture should be considered to be done within the first 3 months of surgery especially in cases with advanced glaucomatous cupping and major visual field defects


Assuntos
Humanos , Masculino , Feminino , Esclera/transplante , Transplante Autólogo/efeitos adversos , Pressão Intraocular , Fibrose , Acuidade Visual
12.
Artigo em Inglês | IMSEAR | ID: sea-45435

RESUMO

PURPOSE: To present the benefit of preserved sclera for immediately repairing perforated corneal ulcer and report the clinical outcome of patients undergoing penetrating keratoplasty after scleral patch graft. PATIENTS AND METHOD: The results of perforated corneal ulcer patients, who underwent penetrating keratoplasty after scleral patch graft between January 1996 and December 2002, were reviewed retrospectively. The causes of the corneal ulcer were also included. RESULTS: Penetrating keratoplasty was performed after scleral patch graft for perforated corneal ulcer on four patients, three males and one female. The culture results from corneal scraping showed Fusarium spp in two cases and Streptococus pneumoniae in one. One patient had a presumed bacterial corneal ulcer. The post-penetrating keratoplasty visual acuity ranged from hand motions to 20/40. CONCLUSION: The scleral patch graft procedure for perforated corneal ulcer may benefit in circumstances of unavailable corneal donors. The results of penetrating keratoplasty after scleral patch graft were favorable.


Assuntos
Administração Tópica , Adulto , Idoso , Anti-Infecciosos/administração & dosagem , Úlcera da Córnea/tratamento farmacológico , Infecções Oculares Fúngicas/complicações , Feminino , Humanos , Ceratoplastia Penetrante/métodos , Masculino , Pessoa de Meia-Idade , Infecções Pneumocócicas/complicações , Reoperação , Estudos Retrospectivos , Esclera/transplante
13.
São Paulo; s.n; 2004. [119] p. ilus, tab, graf.
Tese em Português | LILACS | ID: lil-397831

RESUMO

Para analisar comparativamente, qualitativa e semiquantitativamente, a reação tecidual ao emprego de enxertos homólogos de esclera e dura-máter em olhos de coelhos, foram realizadas cirurgias experimentais em 39 coelhos albinos fêmeas da raça Nova Zelândia. Os olhos foram enucleados e amostras foram colhidas em duas, seis e 12 semanas após o experimento. O enxerto de dura-máter mostrou intensa reabsorção e progressiva substituição por tecido conjuntivo frouxo. O enxerto de esclera mostrou discreta reabsorção na periferia com formação de membrana fibrosa, integrando este à esclera do hospedeiro /A comparative, qualitative and semi-quantitative analysis was made of the tissular reaction to the use of homologous grafts of sclera and dura mater in rabbit eyes. Experimental surgeries were performed in 39 female, albino New Zealand rabbits. The eyes were enucleated and samples collected two, six and 12 weeks after the experiment. The dura mater graft showed intense absorption and progressive substitution by loose connective tissue. The sclera graft presented a discrete absorption in the periphery with formation of a fibrous membrane, becoming integrated with the sclera of the host...


Assuntos
Animais , Coelhos , Dura-Máter/transplante , Esclera/transplante , Transplante Homólogo , Dura-Máter/anatomia & histologia , Coelhos , Técnicas Histológicas/estatística & dados numéricos
14.
An. oftalmol ; 9(1): 92-6, jul. 1990. ilus
Artigo em Português | LILACS | ID: lil-104251

RESUMO

Os implantes de Molteno säo eficientes e capazes de abaixar a pressäo intra ocular e controlar o glaucoma de pacientes fácicos nos quais outras cirurgias falharam, nos pacientes afácicos, nos glaucomas neovasculares e nos glaucomas congênitos. Entre as complicaçöes mais comuns estäo a hemorragia coroideana, catarata, bloqueio do tubo, erosäo conjuntival e extrusäo do tubo, phtisis bulbi, hipotonia e descompensaçäo da córnea


Assuntos
Glaucoma/terapia , Esclera/transplante
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA